Technical Specifications

The GS 32 F0039 PMS used has the following properties:
High frequency performance: frequency up to 240 MHz, with GS-DSP 100 core, suitable for efficient processing of real-time control tasks.
Special command acceleration: Support current loop custom acceleration command (CLU), including Park/inverse Park transform, Clark/inverse Clark transform, PI/PID control, SVPWM and other power control algorithms to improve current control and power regulation performance.
High-precision waveform generation: supports 16 EPWM channels and high-precision HRPWM channels (accuracy 100 ps), suitable for high-precision power regulation and efficient power conversion control.
Enhanced ADC and data acquisition: Built-in two 12-bit SAR-ADCs, support up to 4 MSPS sampling rate, adapt to the accurate voltage and current monitoring requirements of server power supplies.
Powerful computing and storage capabilities: 768 KB eFlash and 416 KB zero-wait SRAM are available to ensure efficient execution of power management algorithms and control tasks.
Modularity and scalability: Support a variety of peripheral interfaces and communication methods (such as SPI, I2C, CAN, etc.), easy to integrate with external devices, flexible to adapt to different server power system requirements.
1. Single-phase totem pole without bridgePFC
The front stage of this scheme adopts single-phase totem pole bridgeless PFC, which works in ** continuous conduction mode (CCM)**. The core features are as follows:
- switching element: AdoptionGaNorSiC MOSFETAs a high speed bridge-arm switching device, it operates at 65 kHz. GaN and SiC are ideal for hard switching circuits due to their extremely small output capacitance and near-zero reverse recovery characteristics.
- rectification designAC line frequency synchronous rectifier arm works at power frequency, usinglow on-resistanceSi MOSFETEffectively reduce rectifier power consumption and improve the overall efficiency of PFC.
- control algorithm: AdoptionDouble Closed Loop Control System with Voltage Outer Loop and Current Inner Loop:
- voltage outer loop: Ensure stable DC voltage output.
- current inner loop: Ensure low harmonic characteristics of inductor current, improve output voltage response speed through current inner loop control, and timely CBC protection and current limiting functions.

2. two-phase staggered parallel connectionLLC
The latter stage of the scheme is designed withtwo-phase staggered parallel half-bridgeLLCtopologyThe advantages are as follows:
- switching element: Original side useGaNorSiC MOSFET, resonant frequency of about 80 kHz, secondary side adoptedsynchronous rectifierThis greatly reduces rectifier power consumption and improves overall system efficiency.
- control algorithm: AdoptionVoltage loop control output voltage, and obtain FM signal through PI regulation, output original and secondary side drive signal through primary side dead zone regulation module and SR dead zone regulation module respectively, wherein primary side drive signal is sent to primary side drive chip through digital isolator.